Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-89
Content
Address
Function
Bit 4-5
00B: No function
01B: FWD
10B: REV
11B: Change direction
Bit 6-7
00B: 1st accel/decel
01B: 2nd accel/decel
10B: 3rd accel/decel
11B: 4th accel/decel
Bit 8-11
Represented 16 step speeds.
Bit 12
1: disable bit 06-11
00B: No function
01B: operated by digital keypad
02B: operated by Pr.00-15 setting
Bit 13~14
03B: change operation source
Bit 15
Reserved
2001H Frequency command
Bit 0
1: EF (external fault) on
Bit 1
1: Reset
Bit 2
1: B.B. ON
2002H
Bit 3-15
Reserved
2100H Error code: refer to Pr.06-16 to Pr.06-21
00: Stop
Status
monitor Read
only
01: deceleration
10: Ready for operation
Bit 0-Bit 1
11: operation
Bit 2
1:JOG command
00: FWD command, FWD output
01: FWD command, REV output
10: REV command, FWD output
Bit 3-Bit 4
11: Reserved
Bit 5
Reserved
Bit
6
Reserved
Bit
7
Reserved
Bit 8
1: Master frequency Controlled by communication
interface
Bit 9
1: Master frequency controlled by analog/external
terminals signal
Bit 10
1: Operation command controlled by
communication interface
Bit 11
1: Parameters have been locked
Bit 12
1: enable to copy parameter from keypad
2119H
Bit 13-15
Reserved
2102H Frequency command (F)
2103H Output frequency (H)
2104H Output current (AXXX.X)
2105H DC-BUS Voltage (UXXX.X)
2106H
Output
voltage
(EXXX.X)
2107H Current step number of Multi-Step Speed Operation
2116H
Multi-function
display (Pr.00-04)