beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 130

background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-89

Content

Address

Function

Bit 4-5

00B: No function
01B: FWD
10B: REV
11B: Change direction

Bit 6-7

00B: 1st accel/decel
01B: 2nd accel/decel
10B: 3rd accel/decel
11B: 4th accel/decel

Bit 8-11

Represented 16 step speeds.

Bit 12


1: disable bit 06-11

00B: No function

01B: operated by digital keypad

02B: operated by Pr.00-15 setting

Bit 13~14

03B: change operation source

Bit 15

Reserved

2001H Frequency command

Bit 0

1: EF (external fault) on

Bit 1

1: Reset

Bit 2

1: B.B. ON

2002H

Bit 3-15

Reserved

2100H Error code: refer to Pr.06-16 to Pr.06-21

00: Stop

Status

monitor Read

only

01: deceleration

10: Ready for operation

Bit 0-Bit 1

11: operation

Bit 2

1:JOG command
00: FWD command, FWD output
01: FWD command, REV output
10: REV command, FWD output

Bit 3-Bit 4

11: Reserved

Bit 5

Reserved

Bit

6

Reserved

Bit

7

Reserved

Bit 8

1: Master frequency Controlled by communication

interface

Bit 9

1: Master frequency controlled by analog/external

terminals signal

Bit 10

1: Operation command controlled by

communication interface

Bit 11

1: Parameters have been locked

Bit 12

1: enable to copy parameter from keypad

2119H

Bit 13-15

Reserved

2102H Frequency command (F)

2103H Output frequency (H)

2104H Output current (AXXX.X)

2105H DC-BUS Voltage (UXXX.X)

2106H

Output

voltage

(EXXX.X)

2107H Current step number of Multi-Step Speed Operation

2116H

Multi-function

display (Pr.00-04)