beautypg.com

4 low voltage (lv) – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 150

background image

| BLD-E1 Series

Revision May 2009, 00DE, V0.50

5-3

5.4 Low Voltage (Lv)

Low voltage

Is input power corr ect? O r power cut,
including momentary power l os s

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

Restart after r eset

Check if there is any malfunc tion
component in

power s upply ci rcuit

or disconnection

Change defectiv e component
and check c onnection

Check if voltage is
within speci fic ation

Make nec essary cor rections,
such as c hange power supply

sy stem for r equirement

Check if there is heavy load
with high s tar t curr ent in the

same power sys tem

Check if Lv occurs when
breaker and magnetic

contactor i s O N

Suitable
transformer

power

capacity

Check if voltage between+
and - is greater than

200VDC (for 115V/230V models)
400VDC (for 460V models)

Maybe br ushless DC motor dr ive has
malfunction. Please c ontact DE LTA.

Contr ol ci rcuit has malfunction or
misoperation due to noise. Pleas e

contact DELTA.

Yes