beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 161

background image

Chapter 6 Fault Code Information and Maintenance| BLD-E1 Series

6-4

Revision May 2009, 00DE, V0.50

Fault

Name

Fault Descriptions

Corrective Actions

IGBT overheating
IGBT temperature exceeds
protection level
1 to 30HP: 100

o

C

1.

Ensure that the ambient temperature falls

within the specified temperature range.

2.

Make sure that the ventilation holes are not

obstructed.

3.

Remove any objects from the heatsinks and

check for possible dirty heat sink fins.

4.

Check the fan and clean it.

5.

Provide enough spacing for adequate

ventilation.

IGBT overheating

Return to the factory

Overload
The brushless DC motor drive
detects excessive drive output
current.

NOTE: The brushless DC
motor drive can withstand up
to 150% of the rated current
for a maximum of 60 seconds.

1.

Check whether the motor is overloaded.

2.

Take the next higher power brushless DC

motor drive model.

Motor 1 overload

1.

Check whether the motor is overloaded.

2.

Check whether the rated current of motor

(Pr.05-01) is suitable

3.

Take the next higher power brushless DC

motor drive model.

Electronic Thermal Relay 1
Protection

1.

Check whether the motor is overloaded.

2.

Check whether motor rated current setting

(Pr.05-01) is suitable

3.

Check electronic thermal relay function

(Pr.06-05~ Pr.06-07)

4.

Take the next higher power brushless DC

motor drive model.

Electronic Thermal Relay 2
Protection

1.

Check whether the motor is overloaded.

2.

Check whether motor rated current setting

(Pr.05-01) is suitable

3.

Check electronic thermal relay function

(Pr.06-05~ Pr.06-07)

4.

Take the next higher power brushless DC

motor drive model.