beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 102

background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-61

03-12

Analog Input Delay Time (VR)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.05

03-13

Analog Input Delay Time (ACI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.05

03-14

Analog Input Delay Time (AVI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.05

Settings

0.00 to 2.00 sec

Interferences commonly exist with analog signals, such as those entering VR, ACI and AVI.

These interferences constantly affect the stability of analog control and using the Input Noise

Filter will create a more stable system.

If time setting is large, the control will be stable, yet the response to the input will be slow. If

time setting is small, the control may be unstable, yet the response to the input will fast.

03-15

Loss of the ACI Signal

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings

0

Disable

1

Continue operation at the last frequency

2

Decelerate to stop 0Hz

3

Stop immediately and display E.F.

This parameter determines the behavior when ACI (4-20mA) is lost. This parameter

determines the behavior when ACI (4-20mA) is lost. This parameter determines the behavior