Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 123
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-82
Revision May 2009, 00DE, V0.50
09-04
Communication Protocol
Control
mode
VF
VFPG
FOCPM
Factory Setting: 1
Settings
0
Modbus
ASCII
mode, protocol <7,N,1>
1
Modbus ASCII mode, protocol <7,N,2>
2
Modbus ASCII mode, protocol <7,E,1>
3
Modbus ASCII mode, protocol <7,O,1>
4
Modbus ASCII mode, protocol <7,E,2>
5
Modbus ASCII mode, protocol <7,O,2>
6
Modbus ASCII mode, protocol <8,N,1>
7
Modbus ASCII mode, protocol <8,N,2>
8
Modbus ASCII mode, protocol <8,E,1>
9
Modbus ASCII mode, protocol <8,O,1>
10
Modbus ASCII mode, protocol <8,E,2>
11
Modbus ASCII mode, protocol <8,O,2>
12
Modbus RTU mode, protocol <8,N,1>
13
Modbus RTU mode, protocol <8,N,2>
14
Modbus RTU mode, protocol <8,E,1>
15
Modbus RTU mode, protocol <8,O,1>
16
Modbus RTU mode, protocol <8,E,2>
17
Modbus RTU mode, protocol <8,O,2>
Computer Control /Computer Link
Before using RS-485 Serial Interface, each drive needs to pre-assign a communication
address specified by Pr.9-00. The computer then controls each brushless DC drive according
to its communication address
A BLD-E1 can be set up to communicate in MODBUS networking using ASCII
mode(American Standard Code for Information Interchange), each 8-bit data is a combination
of 2 ASCII character. For example, a 1-byte data: 64Hex, shown as ‘64’ in ASCII, consists of
‘6’ (36Hex) and ‘4’ (34Hex).
1. Code Description:
ASCII mode:
Each 8-bit data is the combination of two ASCII character. For example, a 1-byte data:
64 Hex, shown as ‘64’ in ASCII, consists of ‘6’ (36Hex) and ‘4’ (34Hex).
Character ‘0’ ‘1’ ‘2’ ‘3’ ‘4’ ‘5’ ‘6’ ‘7’
ASCII
code 30H 31H
32H
33H
34H
35H 36H 37H
Character ‘8’ ‘9’ ‘A’ ‘B’ ‘C’ ‘D’ ‘E’ ‘F’
ASCII
code 38H 39H
41H
42H
43H
44H 45H 46H