4-7

Parameter Explanation

Settings

Factory

Setting

VF VFPG FOCPM

01.18

Accel Time 4

0.00~600.00 sec

3.00

01.19

Decel Time 4

0.00~600.00 sec

2.00

01.20 Reserved

01.21 Reserved

01.22 Reserved

01.23 Switch

Frequency

between 1st/4th

Accel/decel

0~4000rpm (0~400.00Hz)

0 (0.00) ○

01.24 S-curve

for

Acceleration

Departure Time S1

0.0~25.0 sec

0.0

01.25 S-curve

for

Acceleration Arrival

Time S2

0.0~25.0 sec

0.0

01.26 S-curve

for

Deceleration

Departure Time S3

0.0~25.0 sec

0.0

01.27 S-curve

for

Deceleration Arrival

Time S4

0.0~25.0 sec

0.0

01.28

Mode Selection when

Frequency < Fmin

0

:Output waiting

1

:Zero-speed operation

2

: Fmin (4

th

output frequency

setting)

0

01.29 Switch

Frequency

form S to S5

0~4000rpm (0~400.00Hz)

0 (0.00) ○

01.30 S-curve

for

Deceleration Arrival

Time S5

0.0~25.0 sec

0.0

01.31 Time

required

for

deceleration to stop

0.00~600.00 sec

2.00

NOTE: With Delta ECMD-E9 Series motor, rated frequency is 2000rpm and maximum frequency is