Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 48
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-7
Parameter Explanation
Settings
Factory
Setting
VF VFPG FOCPM
01.18
Accel Time 4
0.00~600.00 sec
3.00
○
○
○
01.19
Decel Time 4
0.00~600.00 sec
2.00
○
○
○
01.20 Reserved
01.21 Reserved
01.22 Reserved
01.23 Switch
Frequency
between 1st/4th
Accel/decel
0~4000rpm (0~400.00Hz)
0 (0.00) ○
○
○
01.24 S-curve
for
Acceleration
Departure Time S1
0.0~25.0 sec
0.0
○
○
○
01.25 S-curve
for
Acceleration Arrival
Time S2
0.0~25.0 sec
0.0
○
○
○
01.26 S-curve
for
Deceleration
Departure Time S3
0.0~25.0 sec
0.0
○
○
○
01.27 S-curve
for
Deceleration Arrival
Time S4
0.0~25.0 sec
0.0
○
○
○
01.28
Mode Selection when
Frequency < Fmin
0
:Output waiting
1
:Zero-speed operation
2
: Fmin (4
th
output frequency
setting)
0
○
○
01.29 Switch
Frequency
form S to S5
0~4000rpm (0~400.00Hz)
0 (0.00) ○
○
○
01.30 S-curve
for
Deceleration Arrival
Time S5
0.0~25.0 sec
0.0
○
○
○
01.31 Time
required
for
deceleration to stop
0.00~600.00 sec
2.00
○
○
○
NOTE: With Delta ECMD-E9 Series motor, rated frequency is 2000rpm and maximum frequency is
3000rmp.