beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 167

background image

Chapter 6 Fault Code Information and Maintenance| BLD-E1 Series

6-10

Revision May 2009, 00DE, V0.50

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any peculiar smell or
insulator cracks due to
overheating

Visual inspection, smell

{

If there is any disconnection Visual

inspection

{

If the connected terminal is
normal?

Measure with multimeter with standard
specification

{

Transformer and reactor of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any abnormal vibration
or peculiar smell

Visual inspection

{

Magnetic contactor and relay of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there is any vibration noise
during operation?

Aural inspection

{

If the contact works correctly

Visual inspection

{

Printed circuit board and connector of main circuit

Maintenance

Period

Check Items

Methods and Criterion

Daily

Half

Year

One

Year

If there are any loose screws and
connectors

Tighten the screws and press the
connectors firmly in place.

{

If there is any peculiar smell and
color change

Visual inspection and smell

{