Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 75

background image

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-34

Revision May 2009, 00DE, V0.50

00-02

Parameter Reset

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings

0

No

Function

10 All parameters are reset to factory settings

When it is set to 10, all parameters will be reset to factory settings.

00-03

Start-up Display Selection

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings 0

Display the frequency command value. (F)

1

Display the actual output frequency (H)

2

DC BUS voltage (V)

3

Display the output current (A)

4

Output voltage (E)

5

Multifunction display, see Pr.00-04

This parameter determines the start-up display page after power is applied to the drive. User

defined options are displayed according to Pr.00-04.

00-04

Content of Multi-Function Display

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings 0 Display the output current in A supplied to the motor

1

Reserved

2 Display actual output frequency (H)

3

Display the actual DC BUS voltage in VDC of the

brushless DC motor drive (U)

4

Display the output voltage in VAC of terminals U, V,

W to the motor (E)

5

Display the power factor angle in º of terminals U, V,

W to the motor (n.)

6

Display the output power in kW of terminals U, V

and W to the motor (kW)

7

Display the actual motor speed in rpm (enabled

when using with PG card).

8

Display the estimated value of torque in % as it

relates to current.

9 Display PG position