Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-53
02-09
Digital Input Response Time
Control
mode
VF
VFPG
FOCPM
Factory setting: 0.005
Settings
0.001~ 30.000 sec
This parameter is used for digital input terminal signal delay and confirmation. The delay time
is confirmation time to prevent some uncertain interferences that would result in error (except
for the counter input) in the input of the digital terminals (FWD, REV and MI1~6). Under this
condition, confirmation for this parameter could be improved effectively, but the response time
will be somewhat delayed.
02-10
Digital Input Operation Direction
Control
mode
VF
VFPG
FOCPM
Factory setting: 0
Settings
0 ~ 65535
This parameter is used to set the input signal level and it won’t be affected by the
SINK/SOURCE status.
Bit0 is for FWD terminal, bit1 is for REV terminal and bit2 to bit9 is for MI1 to MI8.
User can change terminal status by communicating.
For example, MI1 is set to 1 (multi-step speed command 1), MI2 is set to 2 (multi-step speed
command 2). Then the forward + 2
nd
step speed command=1001(binary)=9 (Decimal). Only
need to set Pr.02-10=9 by communication and it can forward with 2
nd
step speed. It doesn’t
need to wire any multi-function terminal.
bit5 bit4 bit3 bit2 bit1 bit0
MI6 MI5 MI4 MI3 MI2 MI1
02-11
Reserved
02-12
Reserved
02-13
Multi-function Output 3 (MO1)
02-14
Multi-function Output 4 (MO2)
Factory Setting: 0
Settings
VF VFPG
FOCPM
0
:No function
○
○
○
1: Operation indication
○
○
○
2: Operation speed attained
○
○
○