Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-45

01-12

Accel. Time 1

Factory setting: 3.00

01-14

Accel. Time 2

Factory setting: 3.00

01-16

Accel. Time 3

Factory setting: 3.00

01-18

Accel. Time 4

Factory setting: 3.00

Control

mode

VF

VFPG

FOCPM

Settings

0.00~600.00

sec

01-13

Decel. Time 1

Factory setting: 2.00

01-15

Decel. Time 2

Factory setting: 2.00

01-17

Decel. Time 3

Factory setting: 2.00

01-19

Decel. Time 4

Factory setting: 2.00

Control

mode

VF

VFPG

FOCPM

Settings

0.00~600.00

sec

The Acceleration Time is used to determine the time required for the brushless DC motor

drive to ramp from 0Hz to Maximum Output Frequency (Pr.01-00).

The Deceleration Time is used to determine the time require for the brushless DC motor drive

to decelerate from the Maximum Output Frequency (Pr.01-00) down to 0Hz.

The Acceleration/Deceleration Time 1, 2, 3, 4 are selected according to the Multi-function

Input Terminals settings. The factory settings are acceleration time 1 and deceleration time 1.

The larger against torque and inertia torque of the load and the accel./decel. time setting is

less than the necessary value, it will enable torque limit and stall prevention function. When it

happens, actual accel./decel. time will be longer than the action above.

01-00

01-13,15,17,19

01-12,14,16,18

Frequency

Time

Max. Output

Frequency
Frequency

Setting

accel. time

decel. time

Accel./Decel. Time

01-20

Reserved

0-21

Reserved

0-22

Reserved