beautypg.com

Caution – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 23

background image

Chapter 2 Installation and Wiring| BLD-E1 Series

2-4

Revision May 2009, 00DE, V0.50

Figure 3 Wiring for NPN mode and PNP mode

NOTE

Factory
setting

NPN

PNP

Multi-function
input terminals

Don't apply mains voltage into above terminals.

NPN Mode

Factory setting is NPN

O/P

0V

VCC

NOTE

Open collector output

Applicable Output Signal

It needs to connect O/P to multi-function
input terminals for normal operation.

NOTE

Factory
setting

NPN

PNP

Multi-function
input terminals

Don't apply mains voltage into above terminals.

PNP Mode

Factory setting is PNP

NOTE

Complementary output

Applicable Output Signal

It needs to connect O/P to multi-function
input terminals for normal operation.

VCC

O/P

0V

CAUTION!

1.

The wiring of main circuit and control circuit should be separated to prevent erroneous actions.

2.

Please use shield wire for the control wiring and not to expose the peeled-off net in front of the

terminal.

3.

Please use the shield wire or tube for the power wiring and ground the two ends of the shield

wire or tube.

4.

Damaged insulation of wiring may cause personal injury or damage to circuits/equipment if it

comes in contact with high voltage.

5.

The brushless DC motor drive, motor and wiring may cause interference. To prevent the

equipment damage, please take care of the erroneous actions of the surrounding sensors and

the equipment.