background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-35

00-04

Content of Multi-Function Display

10 Display the electrical angle of drive output

11

Display the signal of VR analog input terminal in %.

Range 0~10V corresponds to 0~100%.

12

Display the signal of ACI analog input terminal in %.

Range 4~20mA/0~10V corresponds to 0~100%.

13

Display the signal of AVI analog input terminal in %.

Range -10V~10V corresponds to 0~100%.

14

Reserved

15 Display the temperature of IGBT in

°C.

16 Display digital input status ON/OFF

17 Display digital output status ON/OFF

18

Display

multi-step

speed

19 The corresponding CPU pin status of digital input

20 The corresponding CPU pin status of digital output

21

|

23

Reserved

24 Output AC voltage when malfunction

25 Output DC voltage when malfunction

26 Motor frequency when malfunction

27 Output current when malfunction

28 Output frequency when malfunction

29 Frequency command when malfunction

30 Output power when malfunction

31 Output torque when malfunction

32 Input terminal status when malfunction

33

Output

terminal

status when malfunction

34 Drive status when malfunction

It is used to display the content when LED U is ON. It is helpful for getting the brushless DC

motor drive’s status by this parameter.

Terminal

MI8 MI7 MI6 MI5

MI4

MI3

MI2

MI1 REV

FWD

Status

0 0 1 0 0 0 0 1 1 0