beautypg.com

3 trial run – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 41

background image

Chapter 3 Keypad and Start Up| BLD-E1 Series

3-8

Revision May 2009, 00DE, V0.50

3.3 Trial Run

The factory setting of trial run is by the potentiometer, please operate by the following steps.

1.

After applying the power, setting the parameter according to the motor type in

parameter group 08. (For Delta’s ECMD-E9 Series of motor, the drive will atuo set the

motor parameter to the default value)

2.

Please execute angle detection for the first time operation of Delta ECMD-E9 Motor

and drive. First set 08-00=1 and press RUN, the keypad will show “tun” during the

angle detection. The keypad will return to the main menu after the auto-detection is

finished.

3.

Verify that LED display shows 0~3000RPM (depends on the potentiometer position)

with RPM signal blinking and FWD indicator lighted on.

4.

Please set potentiometer to a low running speed around 100RPM.

5.

Press RUN key for forward running. For ramp to stop, please press STOP/RESET key.

6.

To switch to reverse running, press the MODE key and look for FWD page, then press
UP/DOWN key to REV page to finish setting.

7.

Check following items:

„

Check if the direction of motor rotation is correct.

„

Check if the motor runs steadily without abnormal noise and vibration.

„

Check if acceleration and deceleration are smooth.

If the results of trial run are normal, please start the formal run.