Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-59

Positive to rque

Reverse

03-00~0 2=7

Positive to rque limit

03-00~0 2=8

Neg ative to rque limit

03-00~0 2=9

Reg enerative

torque limit

03-00~0 2=10

Positive/negat ive torque limit

Neg ative Torq ue

Forw ard

03-00~0 2=10

Positive/negat ive torque limit

03-00~0 2=9

Reg enerative

torque limit

03-03

Analog Input Bias 1 (VR)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.0

Settings

-100.0~100.0%

It is used to set the corresponding VR voltage of the external analog input 0.

03-04

Analog Input Bias 1 (ACI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.0

Settings

-100.0~100.0%

It is used to set the corresponding ACI voltage of the external analog input 0.

03-05

Analog Input Bias 1 (AVI)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.0

Settings

-100.0~100.0%

It is used to set the corresponding AVI voltage of the external analog input 0.

The relation between external input voltage/current and setting frequency is equal to -

10~+10V (4-20mA) corresponds to 0~3000rpm.

03-06

Positive/negative Bias Mode (VR)

Control

mode

VF

VFPG

FOCPM

Factory setting: 0