Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 88
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-47
F requenc y
01-12
accel. time
01-13
decel. time
Time
01-25=S2
01-26=S3
01-24=S1
01-27=S4
01-30=S5
01-29
Switch fr equency
for S3/S 4 changes
to S5
01-28
Mode Selection when Frequency< Fmin
Control
mode
VF
VFPG
SVC
Factory setting: 0
Settings
0
Output
Waiting
1
Zero-speed operation
2
Fmin (4th output frequency setting)
When the Brushless DC motor drive is at 0rpm, it will operate by this parameter.
When it is set to 1 or 2, voltage will be output by Fmin corresponding output voltage(Pr.01-08).
01-31
Deceleration Time when Operating without RUN
Command
Control
mode
VF
VFPG
FOCPM
Factory setting: 2.00
Settings
0.00~600.00
Sec
The brushless DC motor drive will stop by the setting of this parameter when canceling RUN
command. Refer to the figure in Pr.01-29 for details.