beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 88

background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-47

F requenc y

01-12
accel. time

01-13
decel. time

Time

01-25=S2

01-26=S3

01-24=S1

01-27=S4

01-30=S5

01-29
Switch fr equency

for S3/S 4 changes
to S5

01-28

Mode Selection when Frequency< Fmin

Control

mode

VF

VFPG

SVC

Factory setting: 0

Settings

0

Output

Waiting

1

Zero-speed operation

2

Fmin (4th output frequency setting)

When the Brushless DC motor drive is at 0rpm, it will operate by this parameter.

When it is set to 1 or 2, voltage will be output by Fmin corresponding output voltage(Pr.01-08).

01-31

Deceleration Time when Operating without RUN

Command

Control

mode

VF

VFPG

FOCPM

Factory setting: 2.00

Settings

0.00~600.00

Sec

The brushless DC motor drive will stop by the setting of this parameter when canceling RUN