Group 01 basic parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 47
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-6
Revision May 2009, 00DE, V0.50
Group 01 Basic Parameters
: The parameter can be set during operation.
Parameter Explanation
Settings
Factory
Setting
VF VFPG FOCPM
01.00 Maximum
Operation
Frequency
120~4000RPM (10~400Hz)
3000
(250)
○
○
○
01.01 1st
Output
Frequency Setting 1
(Base Frequency/
Rated Motor
Frequency
)
0~400.00Hz 60.00
○
○
○
01.02 1st
Output
Voltage
Setting 1
(Base Voltage/ Rated
Motor Voltage
)
230V Series
:0.0V~255.0V
460V Series
:0.0V~510.0V
220.0
440.0
○
○
○
01.03 2nd
Output
Frequency Setting 1
0~400.00Hz 0.50
○
○
01.04
2nd Output Voltage
Setting 1
230V Series
:0.0V~255.0V
460V Series
:0.0V~510.0V
5.0
10.0
○
○
01.05 3rd
Output
Frequency Setting 1
0~400.00Hz 0.50
○
○
01.06
3rd Output Voltage
Setting 1
230V Series
:0.0V~255.0V
460V Series
:0.0V~510.0V
5.0
10.0
○
○
01.07 4th
Output
Frequency Setting 1
0~400.00Hz 0.00
○
○
01.08
4th Output Voltage
Setting 1
230V Series
:0.0V~255.0V
460V Series
:0.0V~510.0V
0.0
0.0
○
○
01.09
Start Frequency
0~4000rpm (0~400.00Hz)
6 (0.5)
○
○
01.10 Output
Frequency
Upper Limit
0~4000rpm (0~400.00Hz)
3000
(250)
○
○
○
01.11 Output
Frequency
Lower Limit
0~4000rpm (0~400.00Hz)
0 (0.00) ○
○
○
01.12 Accel
Time
1
0.00~600.00
sec
3.00 ○
○
○
01.13
Decel Time 1
0.00~600.00 sec
2.00
○
○
○
01.14 Accel
Time
2
0.00~600.00
sec
3.00 ○
○
○
01.15
Decel Time 2
0.00~600.00 sec
2.00
○
○
○
01.16 Accel
Time
3
0.00~600.00
sec
3.00 ○
○
○
01.17
Decel Time 3
0.00~600.00 sec
2.00
○
○
○