beautypg.com

Group 01 basic parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 47

background image

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-6

Revision May 2009, 00DE, V0.50

Group 01 Basic Parameters

: The parameter can be set during operation.

Parameter Explanation

Settings

Factory

Setting

VF VFPG FOCPM

01.00 Maximum

Operation

Frequency

120~4000RPM (10~400Hz)

3000

(250)

01.01 1st

Output

Frequency Setting 1
(Base Frequency/
Rated Motor

Frequency

0~400.00Hz 60.00

01.02 1st

Output

Voltage

Setting 1

(Base Voltage/ Rated

Motor Voltage

230V Series

:0.0V~255.0V

460V Series

:0.0V~510.0V

220.0

440.0

01.03 2nd

Output

Frequency Setting 1

0~400.00Hz 0.50

01.04

2nd Output Voltage

Setting 1

230V Series

:0.0V~255.0V

460V Series

:0.0V~510.0V

5.0

10.0

01.05 3rd

Output

Frequency Setting 1

0~400.00Hz 0.50

01.06

3rd Output Voltage

Setting 1

230V Series

:0.0V~255.0V

460V Series

:0.0V~510.0V

5.0

10.0

01.07 4th

Output

Frequency Setting 1

0~400.00Hz 0.00

01.08

4th Output Voltage

Setting 1

230V Series

:0.0V~255.0V

460V Series

:0.0V~510.0V

0.0

0.0

01.09

Start Frequency

0~4000rpm (0~400.00Hz)

6 (0.5)

01.10 Output

Frequency

Upper Limit

0~4000rpm (0~400.00Hz)

3000

(250)

01.11 Output

Frequency

Lower Limit

0~4000rpm (0~400.00Hz)

0 (0.00) ○

01.12 Accel

Time

1

0.00~600.00

sec

3.00 ○

01.13

Decel Time 1

0.00~600.00 sec

2.00

01.14 Accel

Time

2

0.00~600.00

sec

3.00 ○

01.15

Decel Time 2

0.00~600.00 sec

2.00

01.16 Accel

Time

3

0.00~600.00

sec

3.00 ○

01.17

Decel Time 3

0.00~600.00 sec

2.00