Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-37

Ramp to stop: the brushless DC decelerates the motor to Minimum Output Frequency

Pr.01-09 and stops according to the deceleration time set in Pr.01-07.

Coast to stop: the brushless DC drive stops output instantly upon command, and motor free

run until it comes to a complete stop.

If the machinery is turned off, the motor must also be stopped to avoid waste of power and

for safety concern. It is suggested to set the brake ramp to stop with ramping duration

matches machinery characteristics.

As the machinery is turned off, if it is allowed for motor to spin freely or the inertia load is large,

it is suggested to set the motor to coast to stop.

00-08

Setting of Motor Running Direction

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings

0

:reverse running allowed

1

:reverse running not allowed

2

:forward running not allowed

This parameter prevents the machine damage which caused by fwd/rev motor run error.

00-09

Control Method

Control

mode

VF

VFPG

FOCPM

Factory Setting: 0

Settings

0

V/f

control

1

V/f + Encoder (VFPG)

8

FOC PM control (FOCPM)