Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 51
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-10
Revision May 2009, 00DE, V0.50
Parameter Explanation
Settings
Factory
Setting
VF VFPG FOCPM
02.12 Reserved
02.13
Multi-function
Output (MO1)
0
:No function
41
○
○
○
1: Operation indication
41
○
○
○
2: Operation speed attained
○
○
○
3
:Desired frequency
attained 1 (Pr. 02-25, 02-
26)
○
○
○
4
:Desired frequency
attained 2 (Pr. 02-27, 02-
28)
○
○
○
5: Zero speed (frequency
command)
○
○
○
6: Zero speed with stop
(frequency command)
○
○
○
7: Over torque (OT1) (Pr.
06-05~06-07)
○
○
○
8: Over torque (OT2) (Pr.
06-08~06-10)
○
○
○
9: Drive ready
○
○
○
10
:Low-voltage Detection
(LV
)
○
○
○
11
:Malfunction indication
○
○
○
12
:Reserved ○
○
○
13
:Overheat warning (Pr.
06-14
)
○
○
○
21
:Ove voltage warning
○
○
○
22
:Over-current stall
prevention warning
○
○
○
23
:Over-voltage stall
prevention warning
○
○
○
02.14
Multi-function
Output (MO2)
24
:Drive operation mode
(Parameter: 00.21=0)
○
○
○