beautypg.com

Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 120

background image

Chapter 4 Parameters| BLD-E1 Series

Revision May 2009, 00DE, V0.50

4-79

It is used to set the rated speed of the motor and need to set according to the value indicated

on the motor nameplate.

08-04

Number of Motor Poles

Control

mode

FOCPM

Factory setting: 4

Settings

2

to

96

It is used to set the number of motor poles (must be an even number).

08-05

Rs of Motor

Control

mode

FOCPM

Factory setting: #

Settings

0.000~65.535

Ω

08-06

Ld of Motor

Control

mode

FOCPM

Factory setting: #

08-07

Lq of Motor

Control

mode

FOCPM

Factory setting: #

Settings

0.0~6553.5mH

08-08

Back Electromotive Force

Control

mode

FOCPM

Factory

setting:

#

Settings

0.0~6553.5Vrms

This parameter is used to set back electromotive force (phase-phase RMS value) when the

motor is operated in the rated speed.

It can get RMS value by Pr.08-00=2 (Motor Auto Tuning).

08-09

Angle between Magnetic Pole and PG Origin

Control

mode

FOCPM

Factory setting: 360.0

Settings

0.0~360.0

°

This function is used to measure the angle between magnetic pole and PG origin.