beautypg.com

Group 02 digital – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual

Page 49

background image

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-8

Revision May 2009, 00DE, V0.50

Group 02 Digital

: The parameter can be set during operation.

Parameter

Explanation Settings

Factory

Setting

VF VFPG FOCPM

02.00 2-wire/3-wire

Operation Control

0

:2-wire operation mode1,

FWD/STOP, REV/STOP

1

:2 –wire mode1, FWD/STOP,

REV/STOP (Line Start Lockout)

2

:2-wire mode2, RUN/STOP,

REV/FWD

3

:2-wire mode2, RUN/STOP,

REV/FWD (Line Start Lockout)

4

:3-wire,

5

:3-wire (Line Start Lockout).

0

02.01 Multi-Function

Command Input

(MI3)

0

:no function

1

02.02 Multi-Function

Input (MI4)

1

:Multi-step command 1

2

02.03 Multi-Function

Command Input

(MI5)

2

:Multi-step command 2

3

3

:Multi-step command 3

4

4

:Multi-step command 4

5

:Reset

6

:Reserved

7

:acceleration/deceleration speed

inhibit

8

:the 1st, 2nd

acceleration/deceleration time

selection

9

:the 3rd, 4th

acceleration/deceleration time

selection

10: EF input (Pr.07-28)

11: Reserved

02.04 Multi-Function

Command Input

(MI6)

12: Stop output