Parameter
Explanation Settings
Factory
Setting
VF VFPG FOCPM
02.00 2-wire/3-wire
Operation Control
0
:2-wire operation mode1,
FWD/STOP, REV/STOP
1
:2 –wire mode1, FWD/STOP,
REV/STOP (Line Start Lockout)
2
:2-wire mode2, RUN/STOP,
REV/FWD
3
:2-wire mode2, RUN/STOP,
REV/FWD (Line Start Lockout)
4
:3-wire,
5
:3-wire (Line Start Lockout).
0
○
○
○
02.01 Multi-Function
Command Input
(MI3)
0
:no function
1
○
○
○
02.02 Multi-Function
Input (MI4)
1
:Multi-step command 1
2
○
○
○
02.03 Multi-Function
Command Input
(MI5)
2
:Multi-step command 2
3
○
○
○
3
:Multi-step command 3
4
○
○
○
4
:Multi-step command 4
○
○
○
5
:Reset
○
○
○
6
:Reserved
○
○
○
7
:acceleration/deceleration speed
inhibit
○
○
○
8
:the 1st, 2nd
acceleration/deceleration time
selection
○
○
○
9
:the 3rd, 4th
acceleration/deceleration time
selection
○
○
○
10: EF input (Pr.07-28)
○
○
○
11: Reserved
○
○
○
02.04 Multi-Function
Command Input
(MI6)
12: Stop output
○
○
○