Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-44

Revision May 2009, 00DE, V0.50

01-05

01-03

01-01

01-06

01-04

01-02

01-00

01-07

01-08

01-09

01-11

01-10

1st Output

Voltage Setting 1

Output Frequency
Lower Limit

Frequency output
ranges limitation

Regular V/f Curve

Special V/f Curve

Voltage

4th Freq.

Start Freq.

3rd Freq.

2nd Freq.

1st Freq.

Maximum Output

Frequency

V/f Curve

2nd Output

Voltage Setting 1

3rd Output

Voltage Setting 1

4th Output

Voltage Setting 1

Output Frequency
Upper Limit

Frequency

01-09

Start Frequency

Control

mode

VF

VFPG

Factory setting: 6

Settings

0.00~400.00Hz

To distinguish which frequency should be start frequency, it needs to compare the value of

min. output frequency and start frequency. The larger value will be start frequency.

When min. output frequency > start frequency

When start frequency > min. output frequency

min. output
frequency

start frequency

start frequency

min. output

frequency

01-10

Output Frequency Upper Limit

Control

mode

VF

VFPG

FOCPM

Factory setting: 3000

Settings

0.00~4800rpm

01-11

Output Frequency Lower Limit

Control

mode

VF

VFPG

FOCPM

Factory setting: 0.00

Settings

0.00~4800rpm

The upper/lower output frequency setting is used to limit the actual output frequency. If the

frequency setting is lower than the start-up frequency, it will run with zero speed. If the

frequency setting is higher than the upper limit, it will runs with the upper limit frequency. If

output frequency lower limit > output frequency upper limit, this function is invalid.