Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series

4-56

Revision May 2009, 00DE, V0.50

Settings

Functions

Descriptions

22

Over-current Stall
Prevention Warning

Active when the over-current stall prevention is detected.

23

Over-voltage Stall
prevention Warning

Active when the over-voltage stall prevention is detected.

24

Operation Mode
Indication

Active when the operation command is controlled by external
terminal. (Pr.00-15=1) and PU LED on keypad KPVL-CC01 is
OFF.

25 Forward

Command

Active when the operation direction is forward.

26 Reverse

Command

Active when the operation direction is reverse.

27~30 Reserved

31

Forward running input

Motor forward run (FWD).

32

Reverse running input

Motor Reverse run (REV).

33

Zero Speed (actual
output frequency)

Active when the actual output frequency is 0. (the drive should
be at RUN mode)

34

Zero Speed with Stop
(actual output frequency)

Active when the actual output frequency is 0 or Stop. (the
drive should be at RUN mode)

35~39 Reserved

40

Speed Attained
(including zero speed)

Active when the output frequency reaches frequency setting.

02-15

Reserved

02-16

Reserved

02-17

Reserved

02-18

Reserved

02-19

Reserved

02-20

Reserved

02-21

Reserved

02-22

Reserved

02-23

Multi-output Direction

Control

mode

VF

VFPG

FOCPM

Factory setting: 0

Settings

0 ~ 65535

This parameter is bit setting. If the bit is 1, the multi-function output terminal will be act with

opposite direction. For example, if Pr.02-13 is set to 1 and forward bit is 0, Relay 1 will be ON