Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 97
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-56
Revision May 2009, 00DE, V0.50
Settings
Functions
Descriptions
22
Over-current Stall
Prevention Warning
Active when the over-current stall prevention is detected.
23
Over-voltage Stall
prevention Warning
Active when the over-voltage stall prevention is detected.
24
Operation Mode
Indication
Active when the operation command is controlled by external
terminal. (Pr.00-15=1) and PU LED on keypad KPVL-CC01 is
OFF.
25 Forward
Command
Active when the operation direction is forward.
26 Reverse
Command
Active when the operation direction is reverse.
27~30 Reserved
31
Forward running input
Motor forward run (FWD).
32
Reverse running input
Motor Reverse run (REV).
33
Zero Speed (actual
output frequency)
Active when the actual output frequency is 0. (the drive should
be at RUN mode)
34
Zero Speed with Stop
(actual output frequency)
Active when the actual output frequency is 0 or Stop. (the
drive should be at RUN mode)
35~39 Reserved
40
Speed Attained
(including zero speed)
Active when the output frequency reaches frequency setting.
02-15
Reserved
02-16
Reserved
02-17
Reserved
02-18
Reserved
02-19
Reserved
02-20
Reserved
02-21
Reserved
02-22
Reserved
02-23
Multi-output Direction
Control
mode
VF
VFPG
FOCPM
Factory setting: 0
Settings
0 ~ 65535
This parameter is bit setting. If the bit is 1, the multi-function output terminal will be act with
opposite direction. For example, if Pr.02-13 is set to 1 and forward bit is 0, Relay 1 will be ON