Group 03: Time Parameters

: The parameter can be set during operation.

Parameter

Explanation Settings

Factory

Setting

VF VFPG FOCPM

03.00

Analog Input (VR) 0

:No function

1

03.01 Analog

Input

(ACI)

1

:Frequency command (torque limit

under TQR control mode)

0

03.02

Analog Input 3

2

:Reserved 0

(AVI)

3

: Preload input

4~6

:Reserved

7: Positive torque limit

8: Negative torque limit

9: Regenerative torque limit

10:

Positive/negative torque limit

03.03 Analog

Input

Bias

VR

-100.0~100.0% 0.0

03.04 Analog

Input

Bias

ACI

-100.0~100.0% 0.0

03.05 Analog

Input

Bias

AVI

-100.0~100.0% 0.0

03.06 Positive/negative

Bias Mode VR

0

03.07 Positive/negative

Bias Mode ACI

(can be set to 0 or

1 only)

0

03.08 Positive/negative

Bias Mode AVI

0: Zero bias

1: Serve bias as the center, lower

than bias=bias

2: Serve bias as the center, greater

than bias=bias

3: The absolute value of the bias

voltage while serving as the center

(single polar)

4: Serve bias as the center (single

polar)

0

03.09 Analog

Input

Gain

VR

0.0~500.0% 100.0

03.10 Analog

Input

Gain

ACI

0.0~500.0% 100.0

03.11 Analog

Input

Gain

AVI

0.0~500.0% 100.0

03.12 Analog

Input

Delay

Time VR

0.00

~2.00 sec

0.05