Group 03: time parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 53
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-12
Revision May 2009, 00DE, V0.50
Group 03: Time Parameters
: The parameter can be set during operation.
Parameter
Explanation Settings
Factory
Setting
VF VFPG FOCPM
03.00
Analog Input (VR) 0
:No function
1
○
○
○
03.01 Analog
Input
(ACI)
1
:Frequency command (torque limit
under TQR control mode)
0
○
○
○
03.02
Analog Input 3
2
:Reserved 0
(AVI)
3
: Preload input
○
○
○
4~6
:Reserved
7: Positive torque limit
○
8: Negative torque limit
○
9: Regenerative torque limit
○
10:
Positive/negative torque limit
○
03.03 Analog
Input
Bias
VR
-100.0~100.0% 0.0
○
○
○
03.04 Analog
Input
Bias
ACI
-100.0~100.0% 0.0
○
○
○
03.05 Analog
Input
Bias
AVI
-100.0~100.0% 0.0
○
○
○
03.06 Positive/negative
Bias Mode VR
0
○
○
○
03.07 Positive/negative
Bias Mode ACI
(can be set to 0 or
1 only)
0
○
○
○
03.08 Positive/negative
Bias Mode AVI
0: Zero bias
1: Serve bias as the center, lower
than bias=bias
2: Serve bias as the center, greater
than bias=bias
3: The absolute value of the bias
voltage while serving as the center
(single polar)
4: Serve bias as the center (single
polar)
0
○
○
○
03.09 Analog
Input
Gain
VR
0.0~500.0% 100.0
○
○
○
03.10 Analog
Input
Gain
ACI
0.0~500.0% 100.0
○
○
○
03.11 Analog
Input
Gain
AVI
0.0~500.0% 100.0
○
○
○
03.12 Analog
Input
Delay
Time VR
0.00
~2.00 sec
0.05
○
○
○