B.5 Zero Phase Reactor (RF220X00A)

Dimensions are in millimeter and (inch)

Recommended

Wire Size (mm

2

)

Cable

type

(Note) AWG mm

2

Nominal

(mm

2

)

Qty.

Wiring

Method

≤10 ≤5.3

≤5.5 1

Diagram

A

Single-

core

≤2 ≤33.6

≤38 4

Diagram

B

≤12 ≤3.3

≤3.5 1

Diagram

A

Three-

core

≤1 ≤42.4

≤50 4

Diagram

B

Diagram A
Please wind each wire 4 times around the core.
The reactor must be put at inverter output as
close as possible.

Power

Supply

Zero Phase Reactor

MOTOR

U/T1

V/T2

W/T3

R/L1

S/L2

T/L3

Note: 600V Insulated unshielded Cable

Note 1:

The table above gives approximate wire

size for the zero phase reactors but the selection
is ultimately governed by the type and diameter of
cable fitted i.e. the cable must fit through the
center hole of zero phase reactors.


Note 2:

Only the phase conductors should pass

through, not the earth core or screen.


Note 3:

When long motor output cables are used

an output zero phase reactor may be required to
reduce radiated emissions from the cable

Diagram B
Please put all wires through 4 cores in series
without winding.

U/T1
V/T2

W/T3

R/L1
S/L2

T/L3

Power
Supply

Zero Phase Reactor

MOTOR