Group 08 pm parameters – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 63
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-22
Revision May 2009, 00DE, V0.50
Group 08 PM Parameters
: The parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting
VF VFPG FOCPM
08.00 Motor
Auto
Tuning
0: No function
1: Only for the unloaded motor, auto
measure the angle between
magnetic pole and PG origin (Pr.
08.09)
2: For PM parameters
3: Auto measure the angle between
magnetic pole and PG origin
(Pr.08-09)
0
○
08.01 Full-load
Current
of Motor
40~120%
)*00.01 Amps
#.##
○
08.02 Rated
power
of
Motor
0.00~655.35kW #.##
○
08.03 Rated
speed
of
Motor (rpm)
0~65535 200
○
08.04
Number of Motor
Poles
2~96 10
○
08.05 Rs
of
Motor 0.000~65.535
Ω #
○
08.06 Reserved
08.07
Lq of Motor
0.0~6553.5mH
#
○
08.08 Back
Electromotive
Force
0.0~6553.5Vrms #
○
08.09 Angle
between
Magnetic Pole
and PG Origin
0.0~360.0° 360.0
○
08.10 Magnetic
Pole
Re-orientation
0: Disable
1: Enable
0
○