Group 08 PM Parameters

: The parameter can be set during operation.

Parameter

Explanation

Settings

Factory

Setting

VF VFPG FOCPM

08.00 Motor

Auto

Tuning

0: No function

1: Only for the unloaded motor, auto

measure the angle between

magnetic pole and PG origin (Pr.

08.09)

2: For PM parameters

3: Auto measure the angle between

magnetic pole and PG origin

(Pr.08-09)

0

08.01 Full-load

Current

of Motor

40~120%

)*00.01 Amps

#.##

08.02 Rated

power

of

Motor

0.00~655.35kW #.##

08.03 Rated

speed

of

Motor (rpm)

0~65535 200

08.04

Number of Motor

Poles

2~96 10

08.05 Rs

of

Motor 0.000~65.535

Ω #

08.06 Reserved

08.07

Lq of Motor

0.0~6553.5mH

#

08.08 Back

Electromotive

Force

0.0~6553.5Vrms #

08.09 Angle

between

Magnetic Pole

and PG Origin

0.0~360.0° 360.0

08.10 Magnetic

Pole

Re-orientation

0: Disable

1: Enable

0