Appendix a specifications – Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 170
Revision May 2009, 00DE, V0.50 A-1
Appendix A Specifications
There are 115V, 230V and 460V models in the BLD-E1 series. For 115V models, it is 1-phase
models. For 0.25 to 3HP of the 230V models, there are 1-phase/3-phase models. Refer to following
specifications for details.
Voltage Class
115V Class
Model Number BLD-XXXE1
002
004
007
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
Max. Applicable Motor Output (hp)
0.25
0.5
1.0
Rated Output Capacity (kVA)
0.6
1.0
1.6
Rated Output Current (A)
1.6
2.5
4.2
Maximum Output Voltage (V)
3-Phase Proportional to Twice the Input Voltage
Output Speed (RPM)
1~4000 RPM
Outp
ut R
ati
ng
Carrier Frequency (kHz)
2-15
Rated Input Current (A)
6.4
9
18
Rated Voltage/Frequency
Single phase, 100-120V, 50/60Hz
Voltage Tolerance
±
10%(90~132 V)
In
pu
t Rati
ng
Frequency Tolerance
±
5%(47~63 Hz)
Cooling Method
Natural Cooling
Fan Cooling
Weight (kg)
1.1
1.1
1.4
Voltage Class
230V Class
Model Number BLD-XXXE1
002
004
007
015
022
037
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
1.5
2.2
3.7
Max. Applicable Motor Output (hp)
0.25
0.5
1.0
2.0
3.0
5.0
Rated Output Capacity (kVA)
0.6
1.0
1.6
2.9
4.2
6.5
Rated
Output
Current
(A)
1.6 2.5 4.2 7.5 11.0 17
Maximum Output Voltage (V)
3-Phase Proportional to Input Voltage
Output Speed (RPM)
1~4000RPM
Outp
ut
Rati
ng
Carrier Frequency (kHz)
2-15
Rated Input Current (A)
4.9
6.5
9.3
15.7
24
--
XXXE
121A Rated
Voltage/Frequency
Single 200-240 V, 50/60Hz
Rated Input Current (A)
1.9
2.7
4.9
9
15
20.6
XXXE
123A Rated
Voltage/Frequency
3-phase 200-240V, 50/60Hz
Rated Voltage/Frequency
1-phase/3-phase 200-240V, 50/60Hz
3-phase
200-240V,
50/60Hz
Voltage Tolerance
±
10%(180~264 V)
Inpu
t R
ati
ng
Frequency Tolerance
±
5%(47~63 Hz)
Cooling Method
Natural Cooling
Fan Cooling
Weight
(kg)
1.2 1.2 1.2 1.7
1.7 1.7