Chapter 3 Keypad and Start Up

3.1 Keypad

3.2 Operation Method

3.3 Trial Run

„

Make sure that the wiring is correct. In particular, check that the

output terminals U/T1, V/T2, W/T3 are NOT connected to power

and that the drive is well grounded.

„

Verify that no other equipment is connected to the motor.

„

Do NOT operate the brushless DC motor drive with humid hands.

„

Check if it displays 2000.0 on the digital keypad after power is

applied.

„

It should be stopped when fault occurs during running and refer to

“Fault Code Information and Maintenance” for solution. Please do

NOT touch output terminals U, V, W when power is still applied to

L1/R, L2/S, L3/T even when the brushless DC motor drive has

stopped. It may cause electric shock if touching the output

terminals U, V, W.