Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual
Page 114
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50
4-73
ON
OFF
01-09
07-05
Output freque ncy
Run /Stop
Time
DC Brake Time
DC Brake Time
during St opping
Start
frequen cy
Start-point for
DC brake
time during
stopping
07-0 3
07-0 4
07-06
DC Brake Proportional Gain
Control
mode
VF
VFPG
Factory
Setting:
50
Settings
1
to
500Hz
It is used to set the output voltage gain when brushless DC brake.
07-07
Reserved
07-08
Reserved
07-09
Reserved
07-10
Reserved
07-11
Fan Control
Control
mode
VF
VFPG
FOCPM
Factory Setting: 1
Settings
0
Fan always ON
1
1 minute after DC brushless motor drive stops, fan will be OFF
2
Brushless DC motor drive runs and fan ON, brushless DC motor
drive stops and fan OFF
3
Fan ON to run when preliminary heat sink temperature attained
4
Fan always OFF
This parameter is used for the fan control.
When setting to 3, fan will start to run until temperature is less than 40°C if temperature
exceeds 40°C.
07-12
Reserved
07-13
Reserved