beautypg.com

Special function 3, Age 97 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 97

background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

97

8

Selectable special functions MM..C-503-30

Startup with Integrated AS-Interface

Special function 3

MOVIMOT

®

with adjustable current limitation (switchable via AS-i bit "speed f1/

speed f2"), with reduction of frequency if exceeded

Function descrip-
tion

The current limitation can be set via switch f2. The AS-i bit "speed f1/speed f2" can be
used to toggle between maximum current limit and the current limitation set via switch f2.

Response after
reaching the cur-
rent limitation

After reaching the current limit, the unit reduces the frequency using the current lim-
itation function and if necessary stops the ramp to prevent the current from increas-
ing.

If the unit operates at the current limitation, the status is displayed through rapid
green flashing of the status LED.

In-system values
for setpoint f2/mini-
mum frequency

Switching via AS-i "speed f1/speed f2" between setpoint f1 and setpoint f2 is no
longer possible.

Adjustable current
limits


Selection of cur-
rent limitation via
AS-i bit "speed f1/
speed f2"

51861AXX

6

7

8

5

2

1

ON

S4

4

5

6

3

3

4

5
6

7

8

Switch f2

Detent position

0

1

2

3

4

5

6

7

8

9

10

I

max

[%] of I

N

60

70

80

90

100

110

120

130

140

150

160

AS-i bit "speed f1/speed f2" = 0

AS-i bit "speed f1/speed f2" = 1

Current limitation 160%

Current limitation via switch f2

0

0

I