8 startup with integrated as-interface, 1 important startup instructions, 2 description of the controls – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 90: Setpoint potentiometer f1, Setpoint switch f2, Switch t1, Startup with integrated as-interface 8.1, Important startup instructions, Description of the controls, 8startup with integrated as-interface

90
Operating Instructions – MOVIMOT® MM03C - MM3XC
8
Important startup instructions
Startup with Integrated AS-Interface
8
Startup with Integrated AS-Interface
8.1
Important startup instructions
•
It is essential to comply with the safety notes during installation!
•
Before removing/attaching the MOVIMOT
®
inverter, it must be disconnected
from the power supply system (mains). Dangerous voltages may still be
present for up to 1 minute after shutdown.
•
Ensure before startup that the drive has not been damaged.
•
Check that all protective covers are installed correctly.
•
A minimum switch-off time of 2 seconds must be maintained for the mains contactor
K11.
8.2
Description of the controls
Setpoint potenti-
ometer f1
The potentiometer is used to adjust setpoint f1:
Setpoint f1 is selected via the AS-i bit "speed f1/speed f2".
Setpoint switch f2
The switch is used to adjust setpoint f2:
Setpoint f2 is selected via the AS-i bit "speed f1/speed f2".
Switch t1
For integrator ramp (ramp times based on a setpoint jump of 50 Hz)
05066BXX
[1] Pot. position
1
2
3
4
5
6
7
8
9
10
0
100
f [Hz
[1]
]
2
75
25
50
6
5
f
1
Switch f2
Detent position
0
1
2
3
4
5
6
7
8
9
10
Setpoint f2 [Hz]
5
7
10
15
20
25
35
50
60
70
100
3
4
5
6
7
8
Switch t1
Detent position
0
1
2
3
4
5
6
7
8
9
10
Ramp time t1 [s]
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
3
4
5
6
7
8
0
0
I