beautypg.com

Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 129

background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

129

10

Diagnostics of MOVIMOT® standard design

Diagnostics

Fault code 89
Thermal overload of brake coil or
brake coil defective

Extend the set ramp time

Brake inspection (see the section "Inspection and Maintenance")

Contact SEW service

If the fault should occur shortly after the initial enable, check the combination of drive (brake
coil) and MOVIMOT

®

frequency inverter.

For combinations of "MOVIMOT

®

and motor with one lower power increment," check the

position of DIP switch S1/6.

Reset the fault by switching off the 24 V

DC

supply voltage or use MOVILINK

®

.

Fault code 91
Communication error between field-
bus gateway and MOVIMOT

®

(this

fault is generated by the bus mod-
ule)

Check electrical connection between fieldbus gateway and MOVIMOT

®

(RS-485)

The fault is automatically reset after removing the cause, a reset via control word is not pos-
sible.

Faults

Cause / solution