Operating Instructions – MOVIMOT® MM03C - MM3XC

10

Diagnostics of MOVIMOT® with integrated AS-Interface

Diagnostics

Starting the diag-
nostic monitor

1. Isolate MOVIMOT

®

drive from the supply, safeguarding it against unintentional

power-up! Dangerous voltages may still be present for up to 1 minute after
shutdown!

2. Remove screws at MOVIMOT

®

inverter and detach MOVIMOT

®

inverter.

3. Remove a closing plug from the MOVIMOT

®

terminal box.

4. Attach the modular jack plug connector 4/4 (RJ11) to the socket X50. Feed the cable

through the open cable entry.

5. Place the MOVIMOT

®

inverter on the terminal box and secure it.

6. Switch in the electronics supply voltage.

7. Start the MOVITOOLS manager on the PC. The following window displays:

8. In the "PC-COM" selection menu, select the serial interface used in your PC.

9. Activate the button "Single Inverter (Peer-to-Peer)" in the window area "Connect to."

06458AEN