10 0 i – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 83
Operating Instructions – MOVIMOT® MM03C - MM3XC
83
7
Startup with MWA21A option (speed control module)
Startup of Standard Design
7. Place the MOVIMOT
®
inverter on the terminal box and secure it.
8. Set the required maximum speed using setpoint potentiometer f1.
9. Re-insert screw plug of setpoint potentiometer f1 with gasket.
10.Select the signal type for the analog input (terminals 7 and 8) of the MWA21A option
using switches S1 and S2.
11.Switch on the voltage.
12.Release MOVIMOT
®
by applying +24 V to tl. 4 (CW rotation) or tl. 5 (CCW rotation)
of the MWA21A.
05066BXX
(1) Pot. setting
S1
S2
Setpoint stop function
V signal 0...10 V
OFF
OFF
No
I signal 0...20 mA
ON
OFF
I signal 4...20 mA
ON
ON
Yes
V signal 2...10 V
OFF
ON
1
2
3
4
5
6
7
8
9
10
0
100
f [Hz
[1]
]
2
75
25
50
6
5
f
1
0
0
I