Selectable special functions MM..C-503-00

Startup of Standard Design

Tripping condi-
tions for fault 84

Fault 84 "Overtemperature Motor" is tripped if all of the following requirements are met:

The standard MOVIMOT

®

motor protection function can be deactivated via DIP

switch S1/5 = ON.

The direction of rotation terminals are wired to 24 V via a TH as shown in the follow-
ing figure.

The TH tripped due to excessive temperature of the motor (release of both direction
of rotation terminals does not apply).

Mains voltage is present.

Special function 6

MOVIMOT

®

with maximum 8 kHz PWM frequency

Function descrip-
tion

The special function reduces the maximum adjustable PWM frequency via S1/7 from
16 kHz to 8 kHz.

When DIP switch S1/7 = "ON", the unit operates with an 8 kHz PWM frequency (low
noise) and switches back to 4 kHz depending on the heat sink temperature.

With field distributor:

52119AXX

With mounting on motor
with option P2.A:

52120AXX

24V

TH

L

R

TH

24V

L

R

TH

If only the 24 V

DC

supply voltage is present at the MOVIMOT

®

, the fault is not initiated.

05601AXX

1

6

7

8

5

4

3

2

ON

S2

6

7

8

5

S1/7

without special function 6

S1/7

with special function 6

ON

PWM frequency variable

16, 8, 4 kHz

PWM frequency variable

8, 4 kHz

OFF

PWM frequency 4 kHz

PWM frequency 4 kHz