Operating Instructions – MOVIMOT® MM03C - MM3XC
8
Advanced startup with MOVITOOLS
Startup with Integrated AS-Interface
Control in manual
mode
The desired signals are set by clicking the corresponding button and reset by clicking it
again. The status is signaled via a symbol (shaded means not active, green means
active). The control signal or parameter bit combination in the device becomes effective
by activating the button.
In the following illustration, the "Reset" control signal and all parameter bits are active
which is indicated by a green symbol:
06369AEN
If the enable is to be carried out in manual mode, the "CW/stop" or "CCW/stop" control
signal and the "Reset/controller enable" control signal must be set. If the "Reset/control-
ler enable" control signal is not set, the device is in the CTRL. INHIBIT status.
0
0
I