Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 63
![background image](/manuals/646387/63/background.png)
Operating Instructions – MOVIMOT® MM03C - MM3XC
63
7
Selectable special functions MM..C-503-00
Startup of Standard Design
Changing the
parameters in
MOVITOOLS
®
Open MOVITOOLS
®
/Shell as follows
•
Select "MOVIMOT
®
" equipment class [1]
•
Under program execution, select "Shell" [2]
After opening MOVITOOLS
®
/Shell, the following parameters are accessible. They can
be changed and stored in the unit.
•
The factory setting is activated as soon as special function 4 is activated via DIP
switches. If the selected special function via DIP switches remains unchanged after
switching off the 24 V operating voltage, the reactivation will use the last known val-
ues from EEPROM.
•
The start frequency is fixed at 0.5 Hz, the stop frequency at 3 Hz.
•
If the set setpoint or the maximum frequency is lower than the set minimum frequen-
cy, the minimum frequency becomes active.
•
The indexes are only evaluated with this special function.
05595AEN
Name
Area
Index
Parameter
number
Step width
Ramp up
0.1...1...2000 [s]
8807
130
0.1 s – 1 s:
0,01
1 s – 10 s:
0,1
10 s – 100 s:
1
100 s – 2000 s: 10
Ramp down
0.1...1...2000 [s]
8808
131
Minimum frequency
2...100 [Hz]
8899
305
0.1
Maximum frequency
1)
2...100 [Hz]
8900
306
0.1
Current limit
60...160 [%]
8518
303
1
Pre-magnetization time
0...0.4...2 [s]
8526
323
0.001
Post-magnetization time
0...0.1...2 [s]
8585
732
0.001
Parameter lock
On/Off
8595
803
–
Factory setting
Yes/No
8594
802
–
Delay time (P501/503)
Speed monitoring
0.1...1...10.0 [s]
8558
501
0.1
Brake release time
0..2 [s]
8749
731
0.001
Slip compensation
2)
0..500 [1/min]
8527
324
0.2
Factory setting = bold
1) Example: Maximum frequency = 60 Hz
Bus setpoint = 10 %
Frequency setpoint = 6 Hz
2) If the special function setting is changed, the value is set to the rated motor slip.
[1]
[2]
0
0
I