Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 114
114
Operating Instructions – MOVIMOT® MM03C - MM3XC
8
Advanced startup with MOVITOOLS
Startup with Integrated AS-Interface
Timeout interval in
manual mode
•
To avoid uncontrolled operation of the device after activating manual mode, a time-
out monitoring in the device becomes effective when the communication is interrupt-
ed, the "Manual mode" window or the program is closed.
•
Manual mode is deactivated after 10 s, and the device changes to control via AS-In-
terface mode.
Performing a reset
To perform a fault reset in manual operation, the "Reset/controller enable" control signal
must be deactivated and then activated since a positive edge from the device must be
recognized for performing the reset. Since the PC interface cyclically requests data from
the device, the message appears after performing the reset.
This message must be acknowledged by clicking the "Ignore" button.
If the timeout monitoring is tripped, the AS-i control signals of the master become
effective immediately. To avoid an unintentional start-up, they must be set in ad-
vance to "no enable".
06373AEN
0
0
I