Connection of movimot, Mm../avsk (connection option a), Mm../avsk – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 42

42
Operating Instructions – MOVIMOT® MM03C - MM3XC
6
Connection of MOVIMOT® MM../AVSK (connection option A)
Electrical Installation with Integrated AS-Interface
6.3
Connection of MOVIMOT
®
MM../AVSK (connection option A)
The following figure shows the connection of the MM../AVSK design.
51823AXX
[1] 24 V
DC
supply
[2] AS-i data cable -
[3] AS-i data cable +
[4] Voltage supply for sensors
[5] Sensor DI2
[6] Sensor DI3
[7] BW.. braking resistor (in MOVIMOT
®
without mechanical brake only)
[8] M12 plug (yellow)
M
3~
L1
L2
L3
PE
K11
F11/F12/F13
13
14
15
L1
L2
L3
24V
AS-i -
AS-i +
VO
VO24
DI2
DI3
BMG
RD
WH
BMG
[1] [2] [3]
[4]
[5]
[6]
BL
BW.
[7]
4
2
1
3
3
1
4
2
AS-I+
AS-I- 24 V
[8]
MM../AVSK