Special function 9 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual
Page 69
Operating Instructions – MOVIMOT® MM03C - MM3XC
69
7
Selectable special functions MM..C-503-00
Startup of Standard Design
Special function 9
MOVIMOT
®
for hoist applications
Pre-requisites
MOVIMOT
®
may only be used in hoist applications if the following pre-requisites
are met:
•
Special function 9 is only possible in connection with brake motors.
•
Ensure that VFC operation (DIP switches S2/3 = OFF) is selected.
•
The use of brake control BGM in connection with an external braking resistor is im-
perative (starting on page 75).
•
It is recommended to activate the function "Speed monitoring" (page 57) .
Function descrip-
tion
•
The start frequency is 2 Hz with terminal and bus operation. If the function is not ac-
tivated, the start frequency is 0.5 Hz.
•
The brake release time is fixed at 200 ms (standard = 0 ms), which prevents the mo-
tor from working against the applied brake.
•
The brake reaction time (post-magnetization time) is 150 ms (standard = 100 ms),
which ensures that the brake is applied as soon as the motor stops generating
torque.
•
The subsequent behavior of MOVIMOT
®
is dependent on the operating mode (see
Overview of brake control with special function 9:
05604AXX
1
6
7
8
5
4
3
2
ON
S2
6
7
8
5
05613AXX
[1] Enable
[2] Pre-magnetization time
[3] Brake control signal
1 = open, 0 = closed
[4] Brake release time
[5] Brake reaction time
(Post-magnetization time)
[6] Frequency
[7] Stop frequency
[8] Start/minimum frequency
[1]
t
t
t
t
150 ms
200 ms
3 Hz
2 Hz
[2]
[3]
[5]
[4]
[6]
[7]
[8]
1
0
0
0
I