beautypg.com

1760-ia12xow6i -29 1760-ow2 -29, Attention – Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual

Page 63

background image

Publication 1760-UM002B-EN-P - March 2005

Installation 2-29

1760-IA12XOW6I

Figure 2.33 1760-IA12XOW6I relay outputs

1760-OW2

Figure 2.34 1760-OW2 relay outputs

Unlike the inputs, the 1760-IB12XOW4IF, 1760-IB12XOW4IOF, and
1760-IA12XOW6I, relay outputs can be connected to different lines.

ATTENTION

Do not exceed the maximum voltage of 250V ac on a relay
contact. If the voltage exceeds this threshold, flashover
may occur at the contact, resulting in damage to the device
or a connected load.

0 V H, N

F 8 A/B 16

L1, L2, L3 (115/230 V h)
+ 24 V
H

25 000

R

24 V H 8 A
115 V
h 8 A
230 V
h 8 A

2 A
2 A
2 A

1000 W

10 x 58 W

1 2

2

2

2

2

2

1

1

1

1

1

10 000 000

S6

S5

S4

S3

S2

S1

+ 24 V H

V

0 V H, N

F 8 A/B 16

L1, L2, L3 (115/230 Vh)

1

2

2

1

10 000 000

S2

S1

25 000

R

24 V H 8 A
115 V
h 8 A
230 V
h 8 A

2 A
2 A
2 A

1000 W

10 x 58 W