Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual
Page 288

Publication 1760-UM002B-EN-P - March 2005
5-20 Visualization with Pico GFX-70
The height of the screen element frame depends on the font size selected.
Three sizes are available:
• Normal font
• Double font
• Quadruple font
You can change the font size by activating the context menu (right mouse
button) or by dragging the selection handle at the bottom edge of the element
frame concerned.
When increasing the font size, ensure that there is sufficient space available
underneath the element.
The width of the screen element frame can be scaled as required by dragging
the selection handle on the sides.
Associated variable tab
- On the Associated variable tab you define the
Boolean variable for activating the numerical value.
Number range/format tab
- The Number range/format tab is used for
defining the following:
• Value range
• Unit of measure
• Scaling range
• Display change
• Showing a signed value
Visibility tab
- The Visibility tab enables you to make the screen element
invisible by means of an associated variable.
Numerical Value Example
The program consists of nine screens that can be selected via the up and down
cursor buttons. The screen change is defined in the Button editor (see Button
Editor on page 5-37).
Standard path:
C:\Program Files\PicoSoft 6 Pro\samples\
Program:
Numerical value_manual screen change.e60
Screen 1 - This screen shows six simple output formats of the numerical values
and provides an overview of the Number range/format properties. The first
screen shows six numerical values. These are associated with the on-delayed
timing relay T04 (Associated variable tab) for which a time range of 4 seconds
is set. The actual value of the timing relay is provided at its QV output (FB
parameter) which is then displayed in the appropriate number format. The
variable type of the associated variable is DWord.