beautypg.com

Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual

Page 197

background image

Publication 1760-UM002B-EN-P - March 2005

Wiring with Pico GFX-70 4-87

The counter has counted 21000 pulses.

Behavior when value range is exceeded

• The function block sets the switching contact CI..CY to status 1.
• The function block retains the value of the last valid operation.

Inputs

The function block inputs

>SH

,

>SL

and

>SV

can have the following operands:

• Constants
• Markers MD, MW, MB
• Analog inputs IA01 to IA04

IA01: terminal I7

IA02: terminal I8

IA03: terminal I11

IA04: terminal I12

• Analog output QA01
• Actual value

QV> of another function block

Actual Value ..QV>

The actual value

QV> can be assigned the following operands:

• Markers MD, MW, MB
• Analog output QA01

IMPORTANT

Counter CI counts every rising edge on the counter input.
If the value range is exceeded, the switching contact CI
..CY switches to status 1 for one cycle per rising edge
detected.

IMPORTANT

The actual value is only erased in RUN mode with a
selective reset signal.