Rockwell Automation 1760-xxxx Pico GFX-70 Controllers User Manual User Manual
Page 282
Publication 1760-UM002B-EN-P - March 2005
5-14 Visualization with Pico GFX-70
Date and Time Example Program 2 – Different Display Formats with Automatic
Screen Change
This program is a copy of the program Date and Time_manual screen
switch.e60 except that the screen change here is automatic. The program
consists of eight screens that can be activated in succession via the counter
C01. The pulse signals are generated with timing relay T01. This produces the
counter values 0 to 9. Counter value 1 activates screen 1, counter value 2
activates screen 2 etc. If upper switch value SH = 9, the counter resets itself.
This therefore produces a continuous loop. The language setting for all eight
screens is “Deutsch”.
Standard path:
C:\Program Files\PicoSoft 6 Pro\samples\
Program:
Date and Time_automatic screen change.e60
Date and Time Example Program 3 – Different Country Settings
The program consists of 11 screens that can be activated automatically via the
counter C01. The pulse signals are generated with timing relay T01. This
produces the counter values 0 to 12. Counter value 1 activates screen 1,
counter value 2 activates screen 2 etc. If upper switch value SH = 12, the
counter resets itself. This therefore produces a continuous loop.
Each screen contains a different country setting. However, this same WD DD
MM YY format is shown.
Standard path:
C:\Program Files\PicoSoft 6 Pro\samples\
Program:
System language_automatic screen change.e60
Figure 5.8 Date display with different country settings
Screen 4
Screen 7
Country
setting
Spanish
MI 01/10/03
Country
setting
Portuguese
QU 01-10-03