Rockwell Automation 294E ArmorStart LT EtherNet/IP Version - User Manual User Manual
Page 250
250
Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Appendix C Using DeviceLogix™
21.
Expand the output tag of the ArmorStart LT, i.e.: Armorstart_LT_36:O
22.
Enter the following value:
23.
Toggle the Armorstart_LT_36_O.RunForward to move the motor in the
forward direction. Then toggle Armorstart_LT_36_O.RunReverse. The
motor will run in the reverse direction.
24.
Change the value of the FreqCommand to vary the speed.
Note:
Setting the tag value to 500 instructs the drive to run at 50.0Hz
This example configuration is now complete. If additional help is needed, please
contact your Rockwell Automation sales representative or technical support.
Name
Value
Description
Armorstart_LT_36:O.FreqCommand
300
30.0Hz, Setting Target Frequency
Armorstart_LT_36_O.RunForward
1
Start the RUNning in Forward Direction