Specifications
Bulletin 294E
Electrical Ratings
Power Circuit
Application
Three-phase
Number of Poles
3
Input Power Terminals
L1, L2, L3
Motor Power Terminals
T1, T2, T3
PE (Earth Ground) Terminal
4 PE terminals
Maximum Rated Operating Voltage
400Y/230…480Y/277 (-15%, +10%)
Rated Impulsed Voltage (U
imp
)
4 kV
Dielectric Withstand
UL: 1960V AC, IEC: 2500V AC
Operating Frequency
50/60 Hz (±10%)
Electrical Ratings — Variable Frequency Drive
Power Circuit
Maximum Rated
Operating Current
Cat. No.
Hp (kW)
Input Amps
400V AC, 50 Hz
Input Amps
480V AC, 60 Hz
Output Amps
294_-FD1P5*
0.5 (0.37)
2.0
1.8
1.5
294_-FD2P5*
1.0 (0.75)
3.7
3.0
2.5
294_-FD4P2*
2.0 (1.5)
6.5
5.5
3.6
Overload Protection
Solid-state I
2
T type
150% for 60 s or 200% for 3 s
Trip Class
Class 10 protection with speed sensitive response and power-down overload retention function
Overcurrent Protection
200% hardware limit, 300% instantaneous fault
Overvoltage Category
III
Reset Mode
Automatic or manual
Output Frequency
0…400 Hz (programmable)
Efficiency
97.5% typical
Overvoltage
380…480V AC Input – Trip occurs at 810V DC bus voltage (equivalent to 575V AC incoming line)
Undervoltage
380…480V AC Input – Trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line)
Control Ride Through
Minimum ride through is 0.5 s — typical value is 2 s
Faultless Power Ride Through
10 ms
Carrier Frequency
2…10 kHz, drive rating based on 4 kHz
Speed Regulation — Open Loop
with Slip Compensation
±2% of base speed across a 40:1 speed range
Acceleration/Deceleration
Two independently programmable acceleration and deceleration times. Each time may
be programmed from 0…600 s, in 0.1 s increments.
Maximum Motor Cable Lengths (Reflected
Wave Protection) ➊
10 m (32 ft)(CE application)➋
14 m (45.9 ft) (non-CE application)
Source Brake (EM Brake) Current
Maximum load current of 3 A
➊ The reflected wave data applies to all frequencies 2…10 kHz.
➋ For CE compliant installations refer to the recommended EMI/RFI cord grip accessory. For availability of the quick disconnect three-phase shielded power and motor cable contact your local sales
representative for details.