beautypg.com

Instance 100 – Rockwell Automation 294E ArmorStart LT EtherNet/IP Version - User Manual User Manual

Page 198

background image

198

Rockwell Automation Publication 290E-UM001B-EN-P - June 2012

Appendix B

CIP Information

Instance 100

Instance 100 is the Configuration Assembly for Bulletin 290E and 291E units.

Instance 100 for Bulletin 290E/291E Starters

Member Index

Byte Offset

Name

Parameter Instance

0

0

Reserved for Logix

N/A

1

2

AssemblyRevision

N/A

2

4

FLASetting

28

3

6

OLResetLevel

29

4

8

OverloadClass

30

5

10

ProtFltResetMode

41

6

12

ProtectFltEnable

42

7

14

WarningEnable

43

8

16

RunNetFltAction

45

9

18

RunNetFltValue

46

10

20

RunNetIdleAction

47

11

22

RunNetIdleValue

48

12

24

IOPointConfigure

49

13

26

FilterOffOn

50

14

28

FilterOnOff

51

15

30

OutProtFltState

52

16

32

OutProtFltValue

53

17

34

OutNetFltState

54

18

36

OutNetFltValue

55

19

38

OutNetIdleState

56

20

40

OutNetIdleValue

57

21

42

Input00Function

58

22

44

Input01Function

59

23

46

Input02Function

60

24

48

Input03Function

61

25

50

Input04Function

62

26

52

Input05Function

63

27

54

NetworkOverride

64

28

56

CommOverride

65

29

58

KeypadMode

66

30

60

KeypadDisable

67

31

62

OLWarningLevel

69

32

64

JamInhibitTime

70

33

66

JamTripDeley

71

34

68

JamTripLevel

72

35

70

JamWarningLevel

73