Discrete input point object, Class code 0x0008, Discrete output point object – Rockwell Automation 294E ArmorStart LT EtherNet/IP Version - User Manual User Manual

Page 206: Class code 0x0009

background image

206

Rockwell Automation Publication 290E-UM001B-EN-P - June 2012

Appendix B

CIP Information

Discrete Input Point
Object

CLASS CODE 0x0008

The following class attributes are currently supported for the Discrete Input
Point Object:

Six instances of the Discrete Input Point Object are supported. All instances
contain the following attributes:

The following common services will be implemented for the Discrete Input Point
Object:

Discrete Output Point
Object

CLASS CODE 0x0009

The following class attributes are supported:

fo

0x10

No

Yes

Set_Attribute_Single

0x4E

No

Yes

Forward_Close

0x54

No

Yes

Forward_Open

Service Code

Implemented for:

Service Name

Class

Instance

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

2

2

Get

Max Instance

UINT

6

Attribute ID

Access Rule

Name

Data Type

Value

3

Get

Value

BOOL

0 = OFF, 1 = ON

4

Get

Fault Status

BOOL

0 = OK, 1 = Fault

115

Get/Set

Force Enable

BOOL

0 = Disable, 1 = Enable

116

Get/Set

Force Value

BOOL

0 = OFF, 1 = ON

Service Code

Implemented for:

Service Name

Class Instance

0x0E

Yes

Yes

Get_Attribute_Single

0x10

No

Yes

Set_Attribute_Single

Attribute ID

Access Rule

Name

Data Type

Value

1 Get

Revision

UINT

1

2

Get

Max Instance

UINT

8 for Bulletin 290E/291E, 10 for Bulletin 294E