The table below lists Fault Codes, Fault Text, and Fault Help Strings for Drive
units.

14

Under Power Trip

Indicates the internal power supply is below its working level.

Available in units with Integrated Power Supply only

15

Sensor Short

Flags a miswired hardware input point.

16

Output Short

Flags a miswired hardware output point.

17

Fault 17

18

Fault 18

19

Phase Imbalance

Indicates an imbalanced phase current.

20

Fault 20

21

Aux Power Loss

Auxiliary Power was lost or dipped below the minimum threshold.

Not available in units with Integrated Power Supply

22

Fault 22

23

Fault 23

24

Fault 24

25

Fault 25

26

Fault 26

27

NonVol Memory

This is a major fault which renders the unit inoperable.

28

Fault 28

29

Fault 29

30

Hardware Fault

This is a major fault which renders the unit inoperable.

31

Fault 31

32

Fault 32

33

Fault 33

34

Fault 34

35

Fault 35

36

Fault 36

37

Fault 37

38

Fault 38

39

Fault 39

40

Unknown Fault

Table 34 - Fault Codes, Fault Text, and Fault Help Strings for Drive Units

Fault

Code

Fault Text

Help Text

PF4M

Fault

Code

1

Fault 1

2

User Defined

User defined trip has occurred.

3

Motor Overload

The load has drawn excessive current.

7

4

Drive Overload

150% load for 1 min. or 200% load for 3 sec. exceeded.

64

Table 33 - Fault Codes, Fault Text, and Fault Help Strings for DOL and Reversers

Fault

Code

Fault Text

Help Text