beautypg.com

Rockwell Automation 294E ArmorStart LT EtherNet/IP Version - User Manual User Manual

Page 155

background image

Rockwell Automation Publication 290E-UM001B-EN-P - June 2012

155

Bulletin 290E/291E/294E Programmable Parameters

Chapter 4

BrakeMode

This parameter determines the source
brake control mode.
0 = NoBrakeControl
1 = AboveFrequency
2 = AboveCurrent

Parameter Number

89

Related Parameters

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Config.

Units

Minimum Value

0

Maximum Value

2

Default Value

1

BrakeFreqThresh

This parameter determines the frequency
above which the source brake is released.

Parameter Number

90

Related Parameters

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Config.

Units

x.x Hz

Minimum Value

0.0

Maximum Value

999.9

Default Value

0.0

BrakeCurrThresh

This parameter determines the motor
current above which the source brake
is released.

Parameter Number

91

Related Parameters

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Config.

Units

x.xx Amps

Minimum Value

0.0

Maximum Value

8.0

Default Value

0.0

IMPORTANT

For parameter 90 and 91 the value of the threshold can be set beyond the
operational maximum limit of the product, or at a level which may cause
multiple transitions during operation. Threshold values near the operational
levels should be avoided.