Bulletin 290E/291E/294E Programmable Parameters Chapter 4

Trip Status Group

InternalFanRPM

This parameter determines the
Revolutions Per Minute (RPM) of the
internal cooling fan.

Parameter Number

13

Access Rule

GET

Data Type

UINT

Group

Basic Status

Units

RPM

Minimum Value

0

Maximum Value

65535

Default Value

0

ElapsedRunTime

This parameter determines the
accumulated run time displayed in 10 hour
increments.
1 = 10 Hrs

Parameter Number

14

Access Rule

GET

Data Type

UINT

Group

Basic Status

Units

Minimum Value

0

Maximum Value

9999

Default Value

0

DriveTemperature

This parameter determines the
present operating temperature
of the power section.

Parameter Number

15

Access Rule

GET

Data Type

UINT

Group

Basic Status

Units

°C

Minimum Value

0

Maximum Value

9999

Default Value

0

TripStatus

This parameter provides the fault
condition that caused any current trip.

Parameter Number

16

Access Rule

GET

Data Type

WORD

Group

Trip Status

Units

Minimum Value

0

Maximum Value

0xFFFF

Default Value

0